IC706 fan adjustment

I will share again with the instructions for adjusting the fan control for IC706 – first version. Open the bottom cover near the connector for connecting the fan (PA-Unit) is towards the back TRX R63-47ohm large SMD. Carefully remove it with a micro soldering iron and replace it with a value of 100ohm, (constant fan operation). This R63, which you have left to install in place of the original resistor R41-22ohm. (increased revolutions at TX). This modification will make TRX operation more pleasant for you. The modification is already used and functional in practice.

73! OM5AMJ